[2021.5] Get valid NetApp NS0-173 exam questions and NS0-173 pdf for free
Share NetApp NS0-173 exam questions and answers from exam2pass latest updated NS0-173 dumps free of charge.
Get the latest uploaded NS0-173 dumps pdf from google driver online. To get the full NetApp NS0-173 dumps PDF or dumps VCE visit: https://www.exam2pass.com/ns0-173.html (Q&As: 60). all NetApp NS0-173 exam questions have been updated, the answer has been corrected!
Make sure your exam questions are real and effective to help you pass your first exam!
Table Of Content:
- NetApp NS0-173 Dumps Pdf
- NetApp NS0-173 Dumps Youtube
- NetApp NS0-173 Exam Questions
- NetApp Discount Code 2021
[NetApp NS0-173 Dumps pdf] Latest NetApp NS0-173 Dumps PDF collected by exam2pass Google Drive:
https://drive.google.com/file/d/1azEdCqMjaVXqBfEBsFJD8bAiKIFc2NYE/
[NetApp NS0-173 Youtube] NetApp NS0-173 exam questions and answers are shared free of charge from Youtube watching uploads from exam2pass.
Latest Update NetApp NS0-173 Exam Questions and Answers Online Test
QUESTION 1
A customer wants to design a FlexPod configuration based on a CVD that was published 10 months ago. The customer
wants to ensure that they are using the latest hardware and software versions.
In this scenario, which two tools are used to identify the latest supported hardware and software? (Choose two.)
A. NetApp Interoperability Matrix Tool
B. NetApp OnCommand System Manager
C. Cisco UCS Hardware and Software Interoperability Matrix
D. Cisco UCS Director
Correct Answer: CD
C: When using this matrix to determine recommended driver versions for your server configuration, please reference the
server\\’s Blade/Rack Bundle firmware version for the recommended driver in the event that your servers are running
Mixed Firmware from your Infrastructure Bundle.
D: Cisco UCS Director delivers unified, highly secure management for supported compute, network, storage, and
virtualization platforms and for the industry\\’s leading converged infrastructure solutions
Reference: https://ucshcltool.cloudapps.cisco.com/public/# https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-director/release-notes/6-7/cisco-ucsdirector-release-notes-67.html
QUESTION 2
Click the Exhibit button.
You are designing a FlexPod Datacenter solution for Microsoft Windows 2012 with Hyper-V. All hosts will boot from the
SAN, including management hosts. The management hosts are Cisco C-Series servers.
Referring to the exhibit, which adapters are required to boot the management servers from the SAN?
A. two 1GbE NICs
B. two 10GbE CNAs
C. two 10GbE NICs
D. two 8Gb HBAs
Correct Answer: C
QUESTION 3
A customer has a FlexPod Express configuration with a FAS2720 system. The company has opened a new remote
location and will purchase a FlexPod Express configuration with a FAS2750 system. The business requires that the data
be replicated to the new location.
Which two software applications accomplish this task? (Choose two.)
A. SnapVault
B. SnapRestore
C. SnapMirror
D. FlexCache
Correct Answer: CD
FlexClone: Instant virtual copies with file and volume granularity SnapMirror: Integrated data replication technology for
simple, efficient, flexible disaster recovery and backup use cases
Reference: https://www.inneo.ch/files/content/Informationstechnologien/Storage-Server-Netzwerk/datenblatt-netappfas-2700-storage.pdf
QUESTION 4
A customer is designing a FlexPod solution with VMware 6.x in a SAN boot environment using FCoE. The customer has
predetermined the WWPN values for the NetApp LIFs and the UCS vHBAs. The customer is now working on the design
workflow for the SAN boot process.
In this scenario, which three FlexPod environment objects are required for SAN connectivity? (Choose three.)
A. NetApp export policies
B. UCS boot policies
C. UCS IQN pools
D. initiator groups
E. FC zones
Correct Answer: ABC
QUESTION 5
A customer wants to deploy FlexPod for a VDI solution with 10,000 users, each with 10 GB of storage allocated.
To support this configuration, which three components must be sized? (Choose three.)
A. the NetApp AFF storage
B. the fabric interconnect ports
C. the 1GbE ports from user systems
D. the Cisco UCS servers
E. the optical cable length
Correct Answer: BCD
QUESTION 6
Which two Unified Computing System capabilities are required to achieve stateless computing? (Choose two.)
A. templates
B. blade servers
C. service profiles
D. boot from SAN
Correct Answer: BC
Cisco introduced the idea of stateless computing with its blade server design. A Cisco UCS instance allows you to
quickly align computing resources in the data center with rapidly changing business requirements. This built-in flexibility
is determined by whether you choose to fully implement the stateless computing feature. Pools of servers and other
system resources can be applied as necessary to respond to workload fluctuations, support new applications, scale
existing software and business services, and accommodate both scheduled and unscheduled downtime. Server identity
can be abstracted into a mobile service profile that can be moved from server to server with minimal downtime and no
need for additional network configuration.
Reference: https://subscription.packtpub.com/book/networking_and_servers/9781782170662/1/ch01lvl1sec07/lookingat-the-ucs-equipment https://mg.mail.yahoo.com/neo/launch?.rand=c56dardsgif3d
QUESTION 7
You are asked to design a FlexPod solution that meets the minimum requirements and includes Application Centric
Infrastructure (ACI).
Which three Cisco components are required in this scenario? (Choose three.)
A. Cisco UCS B-Series servers
B. Cisco Nexus 9000 Series switches
C. Cisco Nexus 2000 Series Fabric Extender
D. Cisco Nexus 3000 Series switches
E. Cisco UCS Series Fabric Interconnects
Correct Answer: ABE
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/UCS_CVDs/flexpod_esxi55u2_n9k_aci_aff8040_design.html
QUESTION 8
A customer has installed FlexPod and verified that all wiring connections are correct. However, the customer cannot see
any FC LUNs from the NetApp AFF systems.
In this scenario, which three configuration elements should the customer verify? (Choose three.)
A. FC zoning
B. igroup configuration
C. ALUA settings
D. FC portsets E. MTU configuration
Correct Answer: BDE
QUESTION 9
A FlexPod administrator is building a WWN pool for a server that has 33 ports. In this scenario, what is the smallest size
possible for the pool?
A. 33
B. 34
C. 68
D. 66
Correct Answer: D
QUESTION 10
A FlexPod solution has been configured for iSCSI SAN boot with multiple paths between the server and the storage.
In this scenario, how many initiators (IQNs) per server will need to be added in the corresponding igroup in ONTAP?
A. three
B. one
C. four
D. two
Correct Answer: C
The initiator group REST API allows you to create, update, delete, and discover initiator groups, and add and remove
initiators that can access the target and associated LUNs. Reference:
https://library.netapp.com/ecmdocs/ECMLP2858435/html/resources/igroup.html
QUESTION 11
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution
with the Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)
A. Cluster mode
B. Direct Connect mode
C. SingleConnect mode
D. DualWire Management mode
E. Multipath mode
Correct Answer: BCD
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used
exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the
data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire
management. SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card
connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack-Mount Server
directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C-Series Rack-Mount Servers
using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system.
This connection uses a single connection from each VIC to each FI.
Reference: https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_CSeriesIntegration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html
QUESTION 12
Which command would a FlexPod administrator use to determine whether an FC initiator has logged on to the fabric?
A. MDS9148>show fcfwd
B. MDS9148>show fcdomain
C. MDS9148>show fcc
D. MDS9148>show flogi database
Correct Answer: D
Reference: https://www.ciscolive.com/c/dam/r/ciscolive/us/docs/2017/pdf/BRKDCN-1121.pdf
QUESTION 13
A customer with a FlexPod Datacenter design that uses a 4-node FAS8200 for storage wants to add a new workload
that requires high performance. The customer needs to nondisruptively move some workloads from the existing FAS
system to the new storage.
Which storage system would satisfy the requirements?
A. FAS2700
B. AFF A300
C. EF570
D. E2700
Correct Answer: C
Reference: https://www.netapp.com/pdf.html?item=/media/16341-tr-4637pdf.pdf
exam2pass NetApp Discount Code 2021
The latest NetApp exam discount code for 2021. exam2pass is valid throughout the year.
Select the purchased test questions and enter the discount code in the “Promotion Code:” input box to enjoy a 15% discount!
For the full NetApp NS0-173 exam dumps from exam2pass NS0-173 Dumps pdf or Dumps VCE visit: https://www.exam2pass.com/ns0-173.html (Q&As: 60 dumps)
ps.
Get free NetApp NS0-173 dumps PDF online: https://drive.google.com/file/d/1azEdCqMjaVXqBfEBsFJD8bAiKIFc2NYE/